{"id":760,"date":"2026-03-06T04:11:42","date_gmt":"2026-03-06T09:11:42","guid":{"rendered":"https:\/\/en.jssi.or.jp\/en\/?page_id=760"},"modified":"2026-03-06T04:15:40","modified_gmt":"2026-03-06T09:15:40","slug":"whats-si_vc","status":"publish","type":"page","link":"https:\/\/en.jssi.or.jp\/en\/whats-si_vc\/","title":{"rendered":"What's SI\/VC?"},"content":{"rendered":"\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\" id=\"1\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Primer of Seismic Isolation \u201cSI\u201d<\/h2>\n\n\n<p>\u201cSeismic Isolation\u201d is a method of protecting a building from major earthquakes.<br \/>\u201cIsolators\u201d are installed between a building and ground to reduce vibrations that transmit to a building.<br \/>It is as if the building were in a condition of floating in the air above the ground.<br \/>This building is a called a seismically isolated building.<\/p>\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n\n<div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-left\"><a href=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/05\/SI_booklet.pdf\" class=\"vk_button_link btn has-text-color is-style-outline has-vk-color-primary-color btn-sm\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><span class=\"vk_button_link_txt\">Get to know about SI. <\/span><i class=\"fa-solid fa-file-pdf vk_button_link_after\" aria-hidden=\"true\"><\/i><\/div><\/a><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"660\" height=\"380\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/05\/SI-earthquake.jpg\" alt=\"\" class=\"wp-image-1322\" style=\"width:592px;height:auto\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/05\/SI-earthquake.jpg 660w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/05\/SI-earthquake-300x173.jpg 300w\" sizes=\"auto, (max-width: 660px) 100vw, 660px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\" id=\"2\"><div class=\"vk_block-margin-md--margin-top\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Principle of Seismic Isolation<\/h2>\n\n\n\n<h4 class=\"wp-block-heading\">Principle of Seismic Isolation for buildings (Draft)<\/h4>\n\n\n<p>This brochure shows principle, concept, analysis of SI for buildings.<\/p>\n\n\n<div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-left\"><a href=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/05\/Principle_SI.pdf\" class=\"vk_button_link btn has-text-color is-style-outline has-vk-color-primary-color btn-sm\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><span class=\"vk_button_link_txt\">Principle of SI for Blds. (Draft) <\/span><i class=\"fa-solid fa-file-pdf vk_button_link_after\" aria-hidden=\"true\"><\/i><\/div><\/a><\/div>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">What is the system of Seismic Isolation ?<\/h4>\n\n\n<p>The following animations show the properties of buildings during earthquakes.<\/p>\n\n\n<div class=\"wp-block-vk-blocks-border-box vk_borderBox vk_borderBox-background-transparent has-text-color has-vk-color-primary-vivid-color is-style-vk_borderBox-style-solid-kado-tit-inner\"><div class=\"vk_borderBox_title_container\"><i class=\"\"><\/i><h4 class=\"vk_borderBox_title\"><\/h4><\/div><div class=\"vk_borderBox_body\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"430\" height=\"270\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/comparison.gif\" alt=\"\" class=\"wp-image-994\"\/><figcaption class=\"wp-element-caption\">(Left)Conventional building , (Right)SI building<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-vk-blocks-border-box vk_borderBox vk_borderBox-background-transparent has-text-color has-vk-color-primary-vivid-color is-style-vk_borderBox-style-solid-kado-tit-banner\"><div class=\"vk_borderBox_title_container has-background has-vk-color-primary-vivid-background-color\"><i class=\"\"><\/i><h4 class=\"vk_borderBox_title\">Conventional building<\/h4><\/div><div class=\"vk_borderBox_body\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"232\" height=\"229\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/ill_cb.gif\" alt=\"Conventional building\" class=\"wp-image-995\"\/><\/figure>\n\n\n\n<p>These buildings are set on the ground, vibration of earthquakes is brought directly to the superstructure.<br \/>Building vibration is severe, there are possibilities that furniture will move and overturn sometimes, doors distort, and walls crack.<\/p>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-vk-blocks-border-box vk_borderBox vk_borderBox-background-transparent has-text-color has-vk-color-primary-vivid-color is-style-vk_borderBox-style-solid-kado-tit-banner\"><div class=\"vk_borderBox_title_container has-background has-vk-color-primary-vivid-background-color\"><i class=\"\"><\/i><h4 class=\"vk_borderBox_title\">SI building<\/h4><\/div><div class=\"vk_borderBox_body\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"206\" height=\"229\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/ill_sb.gif\" alt=\"SI building\" class=\"wp-image-996\"\/><\/figure>\n\n\n\n<p>Devices are installed between building and the ground, and they absorb energy of vibration during the earthquakes. They can reduce vibration of building.<br \/>Building vibration is very slow, there are few possibilities of the foresaid situations.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">Simulation vehicle for shaking of building during earthquakes \u3000<\/h4>\n\n\n<p>Simulation vehicle is installed seismic isolation system and generating system of earthquake ground motions. The video of the right side shows shaking situation of conventional building during the Kobe earthquake, the video of the left side shows shaking situation of seismically-isolated building during the same earthquake. The difference of shaking is significant, especially reduction of severe shaking is recognized in case of seismic isolation.<\/p>\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n\n<div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-left\"><a href=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/06\/simulation_2.mp4\" class=\"vk_button_link btn has-background has-vk-color-primary-background-color btn-lg\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><i class=\"fa-solid fa-video vk_button_link_before\" aria-hidden=\"true\"><\/i><span class=\"vk_button_link_txt\">Video (32sec)<\/span><\/div><\/a><\/div>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\" id=\"3\"><div class=\"vk_block-margin-md--margin-top\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">SI Devices<\/h2>\n\n\n<p>Generally, isolators and dampers are used. There are three types of isolators as shown below.<\/p>\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">Isolator&nbsp;<\/h4>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><span style=\"font-size: 18px;\"><strong>\u25b6 Elastomeric Isolator<\/strong><\/span><\/p>\n\n\n\n<p>It consists of steel and rubber, it made of sandwiches of soft rubber sheets and hard steel plates as shown in the Photograph. It works as a bearing to sustain the weight of the building and is able to move the building laterally. Soft rubber reduces the building vibration to slow shaking, and hard steel plate contributes to sustain the weight of building.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"257\" height=\"182\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/img_dv01.jpg\" alt=\"Elastomeric Isolator \" class=\"wp-image-997\" style=\"width:323px;height:auto\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><span style=\"font-size: 18px;\"><strong>\u25b6 Slider <\/strong><\/span><\/p>\n\n\n\n<p>The slider has a coating of PTFE and a stainless steel plate finished with smooth surface as a mirror in the Photograph. It works as bearing to sustain the weight of the building and is able to move the building laterally on the surface of the plate with a certain amount of friction.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"257\" height=\"271\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/img_dv02.jpg\" alt=\"Slider \" class=\"wp-image-998\" style=\"width:323px;height:auto\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><strong><span style=\"font-size: 18px;\">\u25b6 Rotating Ball Bearing<\/span><\/strong><\/p>\n\n\n\n<p>It consists of ball bearings with retainers and rails or plates as shown in the Photograph. It works as a bearing to sustain the weight of the building and is able to move the building laterally without friction.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"257\" height=\"173\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/img_dv03.jpg\" alt=\"Rotating Ball Bearing\" class=\"wp-image-999\" style=\"width:323px;height:auto\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><span style=\"font-size: 18px;\"><strong>\u25b6<\/strong><strong>FPS<\/strong><strong>\uff08<\/strong><strong>Friction Pendulum System<\/strong><strong>\uff09<\/strong><\/span><\/p>\n\n\n\n<p>This seismic isolation device utilizes the principle of a pendulum to slowly and greatly absorb the energy of shaking caused by earthquakes. A distinctive feature is that the natural period of the seismic isolation layer is not affected by the weight of the building itself.<\/p>\n<p>Stainless steel sliding plates are integrated into the upper and lower concave plates, which are made by processing thick steel into a spherical shape. A slider with a sliding material attached placed between them moves like a pendulum, absorbing the seismic energy and returning the building to its original position.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"702\" height=\"385\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/4-2-SI_Devices_FPS_FrictionPendulumSystem.png\" alt=\"\" class=\"wp-image-1748\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/4-2-SI_Devices_FPS_FrictionPendulumSystem.png 702w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/4-2-SI_Devices_FPS_FrictionPendulumSystem-300x165.png 300w\" sizes=\"auto, (max-width: 702px) 100vw, 702px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-md--margin-top\"><\/div><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">Damper&nbsp;<\/h4>\n\n\n<p>Usually for a damper is used to suppress vibration, damper is used usually.<br \/>Mainly three types of dampers are used as follows;<\/p>\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:60%\">\n<p><strong><span style=\"font-size: 18px;\">\u25b6Steel damper<\/span><\/strong><\/p>\n\n\n\n<p>It utilizes the elasto-plasticity property of steel.<br \/>The hysteretic loop contributes to energy dissipation. There are two types of steel dampers, one is square in section and other is round in section of the rods as shown in the Photograph.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:40%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"340\" height=\"143\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/img_dv04.jpg\" alt=\"Steel damper\" class=\"wp-image-1000\" style=\"width:532px;height:auto\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/img_dv04.jpg 340w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/img_dv04-300x126.jpg 300w\" sizes=\"auto, (max-width: 340px) 100vw, 340px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><strong><span style=\"font-size: 18px;\">\u25b6 Lead damper<\/span><\/strong><\/p>\n\n\n\n<p>It utilizes the plasticity property of lead. The hysteretic loop contributes to energy dissipation. There are two types of lead dampers, one has a round section and a curved shape as shown in the Photograph and other has a cylindrical plug in core of the elastomeric isolator.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"257\" height=\"201\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/img_dv05.jpg\" alt=\"Lead damper\" class=\"wp-image-1001\" style=\"width:373px;height:auto\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><strong><span style=\"font-size: 18px;\">\u25b6 Oil damper<\/span><\/strong><\/p>\n\n\n\n<p>It utilizes the viscous property of fluid. Oil or silicon are used as the fluid. Viscous resistance contributes to energy dissipation. Oil damper is a cylindrical shape as shown in the Photograph.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"257\" height=\"149\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/img_dv06.jpg\" alt=\"Oil damper\" class=\"wp-image-1002\" style=\"width:373px;height:auto\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><span style=\"font-size: 18px;\"><strong>\u25b6 <\/strong><strong>RDT (Rotary Damping Tube), Viscous damper with amplifying mechanism <\/strong><\/span><\/p>\n\n\n\n<p>The \"damping top\" damping device with an amplification mechanism is a damping device consisting of an amplification section that uses a ball screw, which is widely used in industrial machinery, and a damping section that contains a rotating cylinder and has a gap filled with a viscous material.<\/p>\n<p>The linear motion generated by the displacement of the building is converted into rotational motion whose velocity is amplified by the ball screw, and a large damping force is exerted by the viscous resistance that occurs between the rotor and the outer cylinder of the damping section, which is filled with a viscous material.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"910\" height=\"323\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/4-1-SI_Devices_RDT_RotaryDampingTube.png\" alt=\"\" class=\"wp-image-1751\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/4-1-SI_Devices_RDT_RotaryDampingTube.png 910w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/4-1-SI_Devices_RDT_RotaryDampingTube-300x106.png 300w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/4-1-SI_Devices_RDT_RotaryDampingTube-768x273.png 768w\" sizes=\"auto, (max-width: 910px) 100vw, 910px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\" id=\"4\"><div class=\"vk_block-margin-md--margin-top\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Primer of Vibration Control \"VC\"<\/h2>\n\n\n\n<h4 class=\"wp-block-heading\">What is the system of Vibration Control?<\/h4>\n\n\n<p>Vibration control is a method of protecting buildings from major earthquakes.<\/p>\n<p>\"Vibration control devices\" are installed in a building to reduce the shaking of the building.<\/p>\n<p>In an ordinary building, the energy of an earthquake is transmitted directly to the building, causing it to sway significantly. Absorbing some of the energy of an earthquake, which reduces the shaking of the building.<\/p>\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n\n<div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-left\"><a href=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/05\/VC_booket.pdf\" class=\"vk_button_link btn has-text-color is-style-outline has-vk-color-primary-color btn-sm\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><span class=\"vk_button_link_txt\">Get to know about VC. <\/span><i class=\"fa-solid fa-file-pdf vk_button_link_after\" aria-hidden=\"true\"><\/i><\/div><\/a><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"332\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/Vibration.png\" alt=\"Vibration\" class=\"wp-image-1032\" style=\"width:640px;height:auto\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/Vibration.png 640w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/Vibration-300x156.png 300w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\" id=\"5\"><div class=\"vk_block-margin-md--margin-top\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">VC devices<\/h2>\n\n\n\n<h4 class=\"wp-block-heading\">Family of Vibration Control Devices<\/h4>\n\n\n<p><strong><span style=\"font-size: 18px;\">\u25b6 Metal-based Vibration Control Devices<\/span><\/strong><\/p>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>As the metal deforms, it absorbs and dissipates seismic energy by converting it into heat energy, thereby reducing building sway.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-medium is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"254\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_device_1-300x254.jpg\" alt=\"\" class=\"wp-image-1753\" style=\"width:243px;height:auto\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_device_1-300x254.jpg 300w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_device_1-768x651.jpg 768w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_device_1.jpg 877w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n<p><strong><span style=\"font-size: 18px;\">\u25b6 Liquid-based Vibration Control Devices<\/span><\/strong><\/p>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>Oil or other viscous materials injected into the device resist flow and absorb and dissipate seismic energy by converting it into thermal energy, thereby reducing building sway.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"359\" height=\"273\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_device_2.jpg\" alt=\"\" class=\"wp-image-1754\" style=\"width:240px;height:auto\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_device_2.jpg 359w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_device_2-300x228.jpg 300w\" sizes=\"auto, (max-width: 359px) 100vw, 359px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n<p><strong><span style=\"font-size: 18px;\">\u25b6 Vibration Control Devices Using Soft Materials<\/span><\/strong><\/p>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>By installing soft materials such as rubber inside the vibration control device, the soft(viscoelastic) materials deform greatly during an earthquake, absorbing and dissipating seismic energy by converting it into heat energy, thereby reducing building shaking.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-medium is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"113\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_device_3-300x113.jpg\" alt=\"\" class=\"wp-image-1755\" style=\"width:253px;height:auto\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_device_3-300x113.jpg 300w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_device_3.jpg 392w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n<p><strong><span style=\"font-size: 18px;\">\u25b6 Friction-based Vibration Control Device<\/span><\/strong><\/p>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>Friction materials such as metal and sliding materials are tightened together to reduce building sway by absorbing and dissipating seismic energy by converting it into thermal energy through the frictional force generated when the materials move.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image aligncenter size-medium is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"225\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_device_4-300x225.jpg\" alt=\"\" class=\"wp-image-1756\" style=\"width:256px;height:auto\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_device_4-300x225.jpg 300w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_device_4-1024x768.jpg 1024w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_device_4-768x576.jpg 768w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_device_4.jpg 1333w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-md--margin-top\"><\/div><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">Types of Installation&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; \u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000<\/h4>\n\n\n<p><strong><span style=\"font-size: 18px;\">\u25b6Brace type<\/span><\/strong><\/p>\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7387b849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:20%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:30%\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"350\" height=\"234\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_Installation_1-e1723679422510.jpg\" alt=\"\" class=\"wp-image-1758\" style=\"width:321px;height:auto\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:30%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"350\" height=\"189\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_Installation_2-e1723679441808.jpg\" alt=\"\" class=\"wp-image-1759\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:10%\"><\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n<p><strong><span style=\"font-size: 18px;\">\u25b6Wall type<\/span><\/strong><\/p>\n\n\n<figure class=\"wp-block-image aligncenter size-medium is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"214\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_Installation_3-300x214.jpg\" alt=\"\" class=\"wp-image-1763\" style=\"width:330px;height:auto\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_Installation_3-300x214.jpg 300w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_Installation_3.jpg 590w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n<p><strong><span style=\"font-size: 18px;\">\u25b6Stud type<\/span><\/strong><\/p>\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"371\" height=\"314\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_Installation_4.jpg\" alt=\"\" class=\"wp-image-1765\" style=\"width:350px\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_Installation_4.jpg 371w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/08\/VC_Installation_4-300x254.jpg 300w\" sizes=\"auto, (max-width: 371px) 100vw, 371px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\" id=\"6\"><div class=\"vk_block-margin-md--margin-top\"><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Various types of SI\uff06VC Application Examples<\/strong><\/h2>\n\n\n<p>This information corner provides the various types of SI\uff06VC Application Examples.<\/p>\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n<div class=\"huiji\">\n<div class=\"noto\">\n<p><strong><span style=\"font-size: 18px;\">\u25b6<\/span>The Past Thirty Years and the Future of Seismic Isolation Structures<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n<div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-left\"><a href=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/05\/Menshin88_ProfTakeuchi.pdf\" class=\"vk_button_link btn has-text-color is-style-outline has-vk-color-primary-color btn-sm\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><span class=\"vk_button_link_txt\">Click here for details <\/span><i class=\"fa-solid fa-file-pdf vk_button_link_after\" aria-hidden=\"true\"><\/i><\/div><\/a><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"578\" height=\"384\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/The-Past-Thirty-Years-and-the-Future-of-Seismic-Isolation-Structures.png\" alt=\"\" class=\"wp-image-1048\" style=\"width:610px;height:auto\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/The-Past-Thirty-Years-and-the-Future-of-Seismic-Isolation-Structures.png 578w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/The-Past-Thirty-Years-and-the-Future-of-Seismic-Isolation-Structures-300x199.png 300w\" sizes=\"auto, (max-width: 578px) 100vw, 578px\" \/><\/figure>\n\n\n<p style=\"text-align: center;\">Core-suspended seismic isolation structure<br \/>(Shimizu Corporation Safety &amp; Security Center, 2006)<\/p>\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n<div class=\"huiji\">\n<div class=\"noto\">\n<p><strong><span style=\"font-size: 18px;\">\u25b6ZEB Demonstration Building in Taisei <span style=\"font-size: 16px;\">Technology<\/span> Center<\/span><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n<div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-left\"><a href=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/05\/ZEB_Taisei.pdf\" class=\"vk_button_link btn has-text-color is-style-outline has-vk-color-primary-color btn-sm\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><span class=\"vk_button_link_txt\">Click here for details <\/span><i class=\"fa-solid fa-file-pdf vk_button_link_after\" aria-hidden=\"true\"><\/i><\/div><\/a><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"940\" height=\"308\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/ZEB-Demonstration-Building-in-Taisei-Technology-Center.png\" alt=\"\" class=\"wp-image-1049\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/ZEB-Demonstration-Building-in-Taisei-Technology-Center.png 940w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/ZEB-Demonstration-Building-in-Taisei-Technology-Center-300x98.png 300w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/04\/ZEB-Demonstration-Building-in-Taisei-Technology-Center-768x252.png 768w\" sizes=\"auto, (max-width: 940px) 100vw, 940px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n<div class=\"huiji\">\n<div class=\"noto\">\n<p><strong><span style=\"font-size: 18px;\">\u25b6SI Retrofitting of Buildings of the <span style=\"font-size: 16px;\">Nagano<\/span> Prefectural Government<\/span><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n<div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-left\"><a href=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/05\/Nagano-TDP_r3.pdf\" class=\"vk_button_link btn has-text-color is-style-outline has-vk-color-primary-color btn-sm\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><span class=\"vk_button_link_txt\">Click here for details <\/span><i class=\"fa-solid fa-file-pdf vk_button_link_after\" aria-hidden=\"true\"><\/i><\/div><\/a><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"466\" height=\"209\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/05\/Nagano-2.jpg\" alt=\"\" class=\"wp-image-1154\" style=\"width:648px;height:auto\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/05\/Nagano-2.jpg 466w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2024\/05\/Nagano-2-300x135.jpg 300w\" sizes=\"auto, (max-width: 466px) 100vw, 466px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n<div class=\"huiji\">\n<div class=\"noto\">\n<p><strong><span style=\"font-size: 18px;\">\u25b6Kumamoto Castle Keeps<\/span><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n<div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-left\"><a href=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/Kumamoto_Castle_Keeps.pdf\" class=\"vk_button_link btn has-text-color is-style-outline has-vk-color-primary-color btn-sm\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><span class=\"vk_button_link_txt\">Click here for details <\/span><i class=\"fa-solid fa-file-pdf vk_button_link_after\" aria-hidden=\"true\"><\/i><\/div><\/a><\/div>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1102\" height=\"405\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/Kumamoto_Castle.png\" alt=\"\" class=\"wp-image-2342\" style=\"width:890px;height:auto\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/Kumamoto_Castle.png 1102w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/Kumamoto_Castle-300x110.png 300w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/Kumamoto_Castle-1024x376.png 1024w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/Kumamoto_Castle-768x282.png 768w\" sizes=\"auto, (max-width: 1102px) 100vw, 1102px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n<div class=\"huiji\">\n<div class=\"noto\">\n<p><strong><span style=\"font-size: 18px;\">\u25b6G. Itoya<\/span><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n<div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-left\"><a href=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/G.Itoya_.pdf\" class=\"vk_button_link btn has-text-color is-style-outline has-vk-color-primary-color btn-sm\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><span class=\"vk_button_link_txt\">Click here for details <\/span><i class=\"fa-solid fa-file-pdf vk_button_link_after\" aria-hidden=\"true\"><\/i><\/div><\/a><\/div>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"868\" height=\"488\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/G.Itoya_.png\" alt=\"\" class=\"wp-image-2341\" style=\"aspect-ratio:1.7787215438903288;width:913px;height:auto\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/G.Itoya_.png 868w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/G.Itoya_-300x169.png 300w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/G.Itoya_-768x432.png 768w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/G.Itoya_-320x180.png 320w\" sizes=\"auto, (max-width: 868px) 100vw, 868px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n<div class=\"huiji\">\n<div class=\"noto\">\n<p><strong><span style=\"font-size: 18px;\">\u25b6Nakanoshima Festival Tower West<\/span><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n<div class=\"wp-block-vk-blocks-button vk_button vk_button-color-custom vk_button-align-left\"><a href=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/Nakanoshima_Festival_Tower_West.pdf\" class=\"vk_button_link btn has-text-color is-style-outline has-vk-color-primary-color btn-sm\" role=\"button\" aria-pressed=\"true\" target=\"_blank\" rel=\"noopener\"><div class=\"vk_button_link_caption\"><span class=\"vk_button_link_txt\">Click here for details <\/span><i class=\"fa-solid fa-file-pdf vk_button_link_after\" aria-hidden=\"true\"><\/i><\/div><\/a><\/div>\n\n\n\n<div class=\"wp-block-vk-blocks-spacer vk_spacer vk_spacer-type-margin-top\"><div class=\"vk_block-margin-sm--margin-top\"><\/div><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"995\" height=\"479\" src=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/Nakanoshima_Festival_Tower_West.png\" alt=\"\" class=\"wp-image-2343\" style=\"aspect-ratio:1.7787215438903288;width:925px;height:auto\" srcset=\"https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/Nakanoshima_Festival_Tower_West.png 995w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/Nakanoshima_Festival_Tower_West-300x144.png 300w, https:\/\/en.jssi.or.jp\/en\/wordpress\/wp-content\/uploads\/2026\/03\/Nakanoshima_Festival_Tower_West-768x370.png 768w\" sizes=\"auto, (max-width: 995px) 100vw, 995px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Primer of Seismic Isolation \u201cSI\u201d \u201cSeismic Isolation\u201d is a method of protecting a building from major earthquak [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":-998,"comment_status":"closed","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"vkexunit_cta_each_option":"","footnotes":""},"class_list":["post-760","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/en.jssi.or.jp\/en\/wp-json\/wp\/v2\/pages\/760","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/en.jssi.or.jp\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/en.jssi.or.jp\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/en.jssi.or.jp\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/en.jssi.or.jp\/en\/wp-json\/wp\/v2\/comments?post=760"}],"version-history":[{"count":87,"href":"https:\/\/en.jssi.or.jp\/en\/wp-json\/wp\/v2\/pages\/760\/revisions"}],"predecessor-version":[{"id":2349,"href":"https:\/\/en.jssi.or.jp\/en\/wp-json\/wp\/v2\/pages\/760\/revisions\/2349"}],"wp:attachment":[{"href":"https:\/\/en.jssi.or.jp\/en\/wp-json\/wp\/v2\/media?parent=760"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}